DTA Differential Thermal Scanning Analyzer GA-1909

Product Introduction:  

Differential thermal analysis (DTA) is a technique to measure the temperature difference and temperature relationship between a substance and its reference substance under programmed temperature control. The dTA curve describes the temperature (△T) between the sample and the reference as a function of temperature or time. In DTA tests, sample temperature changes are caused by endothermic or exothermic effects of phase transitions or reactions. Such as: phase transformation, melting, crystal structure transformation, boiling, sublimation, evaporation, dehydrogenation, fracture or decomposition reactions, oxidation or reduction reactions, lattice structure destruction and other chemical reactions.

 

Instrument features:

1. The main control chip of the instrument adopts Cortex-M3 core ARM controller, with faster processing speed and better temperature control.

2. USB two-way communication, more convenient operation.

3. Adopt 7 inch 24bit full-color LCD touch screen, more friendly interface.

4. Platinum rhodium alloy sensor, more high temperature resistance, corrosion resistance, oxidation resistance.

 

Technical parameters:

1. Temperature range: room temperature ~1450℃

2. Range: 0 ~ ±2000μV

3. DTA accuracy: 0.01μV

4. Heating rate: 0.1 ~ 100℃/min

5 temperature resolution: 0.01℃

6 temperature accuracy: ±0.1℃

7. Temperature repeatability: ±0.1℃

8. Temperature control: heating up: program control can be adjusted according to the needs of the parameters

Constant temperature: program control constant temperature time arbitrary setting

9. Furnace body structure: the furnace body adopts the upper cover structure, instead of the traditional lifting furnace body, high precision, easy to operate

10. Atmosphere control: internal program automatically switch

11. Data interface: standard USB interface with data cable and operating software

12. Display mode: 24bit color, 7 inch LCD touch screen display

13. Parameter standard: equipped with standard materials, with a key calibration function, users can calibrate the temperature by themselves

14. Baseline adjustment: Users can adjust the baseline based on the slope and intercept of the baseline

15. Working power supply: AC 220V 50Hz (other specifications can be customized)

 

Test map: glass transition temperature


Aggregate peak information:

Enthalpy 60.2686 j/g .  Peak 238.5 c.   beginning 232.7c .  End point244.1c