Testing Standard 

GB/T 26377-2010 Reverse Reflection Measuring Instrument

GB/T16311-2009 Road Traffic Marking Quality Requirements and Testing Methods

JJG(Traffic)059-2004 Verification Regulation of Reverse Reflection Measuring Instrument

 

Product Introduction

GA-2105 retroreflector is used to measure the retroreflectance of a line. Unit: MCD ·m-2· LX-1.Its research main features are: simulated motor vehicles driving on the highway at night, light irradiation on the road (back reflection material production line, after the reflection, is driving the driver observed the brightness of the situation of indoor, measuring the parameters of the back reflection coefficient, the brightness is night RL value, namely the instrument operation is simple, reliable value, which applies to the laboratory environment, can also be used for field measurement .It is suitable for production, quality supervision, engineering construction, supervision units and other units to measure the retroreflection performance of pavement marking.

 

Functional Characteristic

1. Ergonomic handle design, equipped with caster, light and labor-saving, independent Bluetooth button, one-second starting measurement, no bending;

2. Save 500 sets of test data at a time, and the data can be exported to the computer;

3. High-precision chip data acquisition;

4. Open light path, light leakage compensation technology, not affected by natural light to the measurement;

5. Super long standby and fast charging is supported;

6. 5-inch daylight screen;

7. USB data interface, test report is exported to the computer in the form of database;

8. The detection results are printed on the spot by the Bluetooth printer;

9. Touch the keyboard to input Chinese characters, English and characters;

10. Real-time display of temperature and humidity;

 

Technical Parameters 

Serial number

The name

Technical index

1

Measuring project

Inverse luminance   coefficientmcd·m-2·lx-1

2

Measurement Range

0/2000

3

Observing angle

1.05°

4

Angle of incidence

88.76° The complementary Angle is 1.24°

5

The light source color temperature

2856±50k

6

Measuring window area

 

200mm x 95mm

7

Repeatability error

2%

8

Battery lasts for a long time

30h

9

Data storage space

Store 500 pieces of data at a time

10

Battery capacity

12V/5.2Ah

11

Charging source

DC 15V

12

Ambient temperature

-1560

13

Ambient   thumidity

98% No condensation

14

Lengthwidth and height

580mm x 260mm x 160mm